Central AC Repair in Los Angeles
Repair of central air conditioning in homes across Los Angeles: split systems, heat pumps and package units that stop cooling, cool weakly, leak, freeze up or won't shut off.
$85 service call credited toward repair · 30-day labor / 90-day warranty on parts we supply
Updated November 2026
Quick facts
| Service call | $85 — credited toward the repair when you proceed |
|---|---|
| Warranty | 30-day labor · 90 days on parts we supply |
| Credentials | BEAR #A 50636 · EPA Section 608 Universal |
| Hours | Mon–Fri 09:00–19:00 Sat–Sun 10:00–16:00 |
Capacitors and contactors
Tested with a meter, not guessed: a weak capacitor stops a fan or compressor from starting, and a welded contactor keeps the outdoor unit running.
Condenser fan and blower motors
Burned or overheating motors replaced, and the reason they failed checked: a dead capacitor, dust, or a part that failed early.
Refrigerant leaks found and brazed
EPA Section 608 Universal certified. We find the leak with nitrogen and a detector, repair it, pull a vacuum and charge by the nameplate.
TXV, filter drier and compressor
Restrictions read on the gauges before a part is ordered, so a new compressor doesn't run against the same fault that killed the old one.
Split systems, heat pumps, package units
Condensers in the yard or on the roof, heat pumps, and package units with the whole system in one cabinet.
Book online in Spanish
Online booking in both languages.
How an AC repair visit works
Tell us what the system is doing
Call or book online: no cooling, weak air, ice on the lines, water from the ceiling, an outdoor unit that won't start or won't stop. A photo of the outdoor unit's nameplate helps.
Diagnosis on site
The $85 service call covers the diagnosis. We check the filter and airflow, test the capacitor, contactor and motors, and put gauges on the refrigerant side when the symptoms point there.
Written quote before the work
You get a written flat-rate quote after diagnosis. If you go ahead, the $85 is credited toward the repair.
Repair, then readings
After the repair we run the system and check it: pressures, temperatures, and a vacuum that holds after any leak or brazing work.
Warranty
30 days on labor and 90 days on parts we supply. Parts you supply yourself carry no warranty from us.
What does central AC repair cover?
Epic Star repairs central air conditioning in Los Angeles homes: split systems, heat pumps and package units. We diagnose on site for an $85 service call, credited toward the repair when you proceed, then give you a written flat-rate quote. We repair capacitors, contactors, fan motors, refrigerant leaks, filter driers, TXVs and compressors.
Why is my central air running but not cooling?
An air conditioner moves heat out of the house. The outdoor unit has to start its compressor and fan, the refrigerant has to flow at the right pressures, and air has to move across both coils. When any of those stops, the house warms up. Every example below is a job we did and wrote up.
Is it the capacitor or the condenser fan motor?
A capacitor is what lets the fan motor and compressor start turning. In the Hollywood Hills, a capacitor failed and the condenser fan motor burned out trying to start without it. We replaced the motor. In Pacific Palisades, a new Goodman system lost its condenser fan motor about a month after installation, and we replaced it under the manufacturer’s parts warranty. Without that fan the outdoor unit can’t get rid of its heat, which is hard on the compressor too.
Why won’t the outdoor unit shut off?
The contactor is the switch that sends power to the compressor and the outdoor fan. On a York condenser that kept running, its contacts had welded together. A new contactor fixed it. On an American Standard condenser in Toluca Lake, a stuck contactor was the third fault we found on one visit.
Where did the refrigerant go?
Low refrigerant means a leak, so we look for the leak instead of topping the system off. On an old R-22 system in Van Nuys, two copper lines had rubbed through inside the outdoor unit; we brazed the spot, pressure-tested it and charged by the nameplate. On a heat pump in Santa Monica, the suction service valve had been opened so hard it leaked, and working the stem stopped it. In a newly renovated house in Torrance, the installer had put Teflon tape on the flare fittings and the whole charge had leaked out. On an older R-22 system in Sherman Oaks, the leak search pointed to the condenser coil itself, a part that can’t be reliably repaired.
Is something restricting the refrigerant?
A restriction shows up on the gauges and sometimes as frost. In Winnetka, the line after the filter drier frosted while the line before it didn’t; we brazed in a new drier. In Brentwood, a Lennox compressor had burned out against a stuck-closed TXV, so we replaced both. When a compressor burns out, we look for the fault behind it, or the new one ends up working under the same conditions.
Is the airflow blocked?
An AC can’t cool what it can’t move. In Northridge, a system kept stopping after long runs because a blower motor packed with dust overheated and tripped its thermal protection; in Bel Air, a motor like it had burned out. In Century City, a skipped filter left the evaporator coil packed with dust. Outside, a condenser coil caked with dirt made a Granada Hills system run hot until we cleaned it.
Do you repair heat pumps and package units?
Yes. A heat pump is a central system that can run in reverse to heat, and its cooling side fails the same ways an AC does: capacitors, contactors, fan motors and leaks. A package unit puts the compressor, coils, blower and drain pan in one cabinet on the roof or a pad. In Valley Village, a fairly new Goodman package unit was dripping water into the house through a cracked drain pan, and replacing the pan meant taking the unit almost completely apart. Near the ocean, salt air is its own problem: on a Carrier condenser in Redondo Beach, the coil and fan had corroded beyond repair.
Which page fits your system?
- A system that still runs and needs its seasonal service: AC tune-up.
- A ductless wall, ceiling or ducted mini-split: mini-split repair.
- Window and through-the-wall units are replaced, not repaired: window AC replacement.
- A rooftop unit at a restaurant, salon, clinic or other business: commercial AC and HVAC repair.
- No heat from a furnace, heat pump or package unit: furnace and heating repair.
How much does central AC repair cost in Los Angeles?
Ranges come from repairs we completed in Los Angeles, rounded, and include parts, labor and the $85 service call. Your exact price is quoted in writing after diagnosis, before any work starts.
| Repair category | Typical cost | Our LA jobs |
|---|---|---|
| Coil cleaning (condenser or evaporator) | $280–$570 | 3 jobs |
| Electrical parts and motors (contactor, blower motor, condenser fan motor and capacitor) | $310–$600 | 3 jobs |
| Refrigerant leak repair, filter drier or service valve, plus recharge | $460–$990 | 5 jobs |
| Compressor replacement | $1,100–$2,950 | 3 jobs |
The service call is $85, and it’s credited toward the repair when you proceed. After diagnosis you get a written flat-rate quote, before we start. Repairs carry a 30-day labor warranty and 90 days on parts we supply; parts you supply yourself carry no warranty from us. Furnace, mini-split, commercial and appliance repairs are in our Los Angeles repair cost guide.
Credentials
California BEAR registered (#A 50636), EPA Section 608 Universal certified, $1,000,000 general liability insurance. Online booking in English and Spanish.
Service area
We serve all of Los Angeles: the San Fernando Valley, Hollywood and Mid-City, the Westside, and the beach cities and South Bay.
Call (213) 205-2055
Tell us what the system is doing, and text a photo of the outdoor unit’s nameplate if you can.
Recent AC repairs we've documented
-
Hollywood Hills
Condenser fan motor that burned out after its capacitor failed
- What the customer saw
- Customers in the Hollywood Hills told us their air conditioner wasn't cooling.
- What we found
- The condenser fan motor on the outdoor unit had burned out. The capacitor failed first, and without it the motor couldn't start, so it overheated and burned.
- What we did
- We replaced the condenser fan motor, with the old and new motors side by side on top of the condenser.
-
York condenser that wouldn't shut off
- What the customer saw
- A York condenser kept running with nothing calling for cooling.
- What we found
- The contactor's contacts had welded together. A tap on the contactor released it, and the burn marks were plain around the contacts.
- What we did
- We replaced the contactor. The outdoor unit now shuts off when it should.
-
Toluca Lake
Three faults in one American Standard condenser
- What the customer saw
- A burned-out compressor on an American Standard condenser in a Toluca Lake backyard, on a hot day, and not the first one this unit had lost.
- What we found
- With the new compressor in and the system charged, a restriction showed up: the TXV had seized. After that, the contactor turned out to be stuck as well.
- What we did
- We replaced the compressor and the TXV on one visit and found the contactor stuck.
-
Brentwood
Lennox compressor burnout and the stuck TXV behind it
- What the customer saw
- The compressor in a Lennox system in Brentwood had burned out.
- What we found
- With the new compressor running, suction pressure was far too low while the compressor kept pumping. The TXV was stuck closed, and the old compressor had worked against that restriction until it burned.
- What we did
- We replaced the compressor and the TXV, and the system worked normally after that.
-
Van Nuys
Old R-22 AC that lost its charge to chafed copper
- What the customer saw
- An old R-22 air conditioner in Van Nuys had lost all of its refrigerant.
- What we found
- Inside the outdoor unit, two copper lines had rubbed against each other until the copper wore through. Oil around the rub point gave the leak away.
- What we did
- We brazed the leak, pressure-tested the repair, evacuated the system and recharged it by the nameplate.
-
Santa Monica
Heat pump empty of refrigerant: an over-tightened service valve
- What the customer saw
- A split system in Santa Monica, with an inverter heat pump outside, had stopped cooling and had no refrigerant left.
- What we found
- A nitrogen test at 400 PSI found one leak, around the stem of the suction service valve. Someone had opened the valve so hard that it leaked in that position.
- What we did
- Instead of cutting the valve out, we worked the stem in and back out to fully open without forcing it, and the leak stopped. Then a vacuum and a full charge weighed in from the nameplate.
-
Winnetka
Frost after the filter drier: a restriction in Winnetka
- What the customer saw
- A customer in Winnetka told us their air conditioner wasn't cooling.
- What we found
- There was a big pressure difference between the suction and liquid lines, and the copper coming out of the filter drier frosted while the line going in didn't: a restriction inside the drier.
- What we did
- We pumped the refrigerant down into the condenser, brazed in a new filter drier, checked the screen at the TXV, evacuated the system and started it. The AC worked.
-
Valley Village
Water through the ceiling from a Goodman package unit
- What the customer saw
- Water was running from the ceiling of a house in Valley Village. Up on the roof, the fairly new Goodman package unit was dripping from every side.
- What we found
- The plastic condensate drain pan had a huge crack, most likely from installation or transport.
- What we did
- We took the unit almost completely apart to replace the drain pan.
Photos from our AC repair jobs








Issues we fix
-
Outdoor unit hums but the fan on top doesn't spin
Possible causes:
- Failed capacitor
- Burned-out condenser fan motor
-
Outdoor unit won't shut off
Possible causes:
- Contactor with welded contacts
-
System runs but blows warm air
Possible causes:
- Low refrigerant from a leak
- Restriction at the filter drier or a stuck TXV
- Failed compressor, possibly with another fault behind it
-
Frost or ice on the copper lines
Possible causes:
- Restricted filter drier
- Low charge from a leak
- Clogged air filter or a dirty evaporator coil starving the airflow
-
AC stops after running a long time
Possible causes:
- Blower motor packed with dust overheating and tripping its thermal protection
-
Water coming through the ceiling
Possible causes:
- Cracked condensate drain pan
- Blocked condensate drain
Frequently asked questions
Why is my central air running but not cooling?
Causes include a failed capacitor or condenser fan motor, low refrigerant from a leak, a restriction at the filter drier or TXV, or a clogged filter and dirty coil cutting the airflow. Check the thermostat, the filter and the breaker first. If the fan on top of the outdoor unit isn't spinning, or there's ice on the lines, turn the system off at the thermostat and call.
How much does AC repair cost in Los Angeles?
On central AC repairs we completed in Los Angeles, coil cleaning typically runs $280–$570, electrical parts and motors $310–$600, a refrigerant leak repair with a recharge $460–$990, and a compressor replacement $1,100–$2,950. Those ranges include parts, labor and the $85 service call, which is credited toward the repair when you proceed. Your exact price comes as a written flat-rate quote after diagnosis, before any work starts, and completed repairs carry a 30-day labor warranty and 90 days on parts we supply.
Do you repair refrigerant leaks, or just add refrigerant?
We find the leak first. We are EPA Section 608 Universal certified. On jobs we've documented, the leak was chafed copper inside an outdoor unit, an over-tightened service valve stem, and Teflon tape on flare fittings. We repair the leak, pressure-test it, pull a vacuum and charge the system by the nameplate.
My outdoor unit keeps running with the thermostat off. What's wrong?
We check the contactor first: it may have welded shut. It's the switch that sends power to the compressor and outdoor fan, and when its contacts burn and stick, the unit can't turn off. Switch the system off at the thermostat, then at the breaker if it still runs, and call. Don't open the panel: there's line voltage inside.
Do you repair heat pumps and package units?
Yes. A heat pump cools with the same refrigerant circuit as a central AC, and a package unit keeps the whole system in one cabinet on the roof or a pad. We've repaired a heat pump with a leaking service valve in Santa Monica and a Goodman package unit with a cracked drain pan in Valley Village.
Is this the same as an AC tune-up?
No. This page is for a system that has stopped working right. An AC tune-up is scheduled maintenance on a system that still runs. Mini-splits, window units and commercial rooftop units each have their own page.
What credentials and insurance do you carry?
Our technician is EPA Section 608 Universal certified for refrigerant handling. Epic Star Inc is California BEAR registered (#A 50636) and carries $1,000,000 in general liability insurance.
Google reviews
★★★★★
Eric had a great and warmness about himself, efficient and knowledgeable awareness of the issues. Had accessed and completed the task in a minimal amount of time (12 minutes)
★★★★★
Refrigerator was checked thoroughly and repair ok ok
★★★★★
I’m very glad I had Ivan come to clean the extremely dirty hood over my stove. He came the same afternoon and did a very thorough job. After seeing how much work it was, I was very pleased with the price he charged me. I would definitely recommend this company.
Book a diagnostic/repair visit
Central air not cooling? Book a diagnosis.
Or text a photo of the outdoor unit's nameplate and tell us what the system is doing.