A Goodman package unit in Sherman Oaks with a seized inducer motor: we replaced the whole inducer assembly
In early November 2026, the draft inducer on the gas furnace side of an older rooftop Goodman package unit had seized from age. The new inducer assembly we put in carries a Fasco motor.
In this guide
In early November 2026, the draft inducer motor on this older Goodman package unit in Sherman Oaks had seized from age. We replaced the whole inducer assembly: the motor, the blower wheel and the metal housing. On this unit those three come as one part.
What is a package unit?
The unit in the photo at the top sits on a flat roof. It’s a gas/electric package unit, sometimes called a gas pack: a gas furnace and an air conditioner built into one cabinet. The fan grille on top belongs to the cooling side. The gas furnace sits behind the service panels, and that’s where the inducer is.
Many LA homes and small buildings heat and cool this way, with the unit on the roof or on a pad at ground level. Inside, the furnace side has the same parts as a furnace in an attic or a closet: an inducer, a pressure switch, an igniter, a gas valve, a flame sensor and a control board.
What does the draft inducer do?
The inducer is a small blower with its own motor, mounted on the furnace section. When the thermostat calls for heat, it’s the first thing to start. It pulls air through the burners and the heat exchanger and pushes the exhaust out of the unit.
A pressure switch, connected to the inducer by a small tube on many furnaces, has to close and prove the draft is there. Only then does the board power the igniter and open the gas valve. On our furnace repair page we go through that whole startup sequence step by step.
Why won’t a furnace light when the inducer seizes?
With the motor seized, the wheel doesn’t turn, so there’s no draft and the pressure switch never closes. The board stops the sequence there, and the burners don’t light.
This Goodman is an older unit, and its inducer motor had seized from age. Here is the old assembly, out of the unit and set on the unit’s top panel.

This is the side that faces the furnace. The blower wheel with its row of thin blades sits in the round opening, and the outlet on the right has rust around its rim. The motor is on the other side of the plate.

With the assembly turned over, you can see the motor bolted to the housing, its tape-wrapped coil and its two leads, and the curved outlet the exhaust leaves through.
Why replace the whole assembly instead of just the motor?
This Goodman didn’t leave a motor-only option. Its motor comes attached to the wheel and the housing.
That isn’t true of every furnace. On some models only the motor can be replaced, but only if the blower wheel can be taken off the old motor shaft. After years outdoors, that wheel is often rusted onto the shaft, and forcing it off can bend or crack it. When the wheel won’t come off cleanly, or the motor isn’t sold on its own, the assembly is the repair.

In this photo the new assembly is installed on the furnace side of the unit. The label on the new motor reads Fasco. The gray tube from the housing runs up out of the frame, and on many furnaces that’s the kind of tube that goes to the pressure switch.
Why do inducer motors on rooftop units seize?
In general, an inducer motor runs every time the heat comes on, winter after winter. On a package unit it lives outdoors with the rest of the furnace, out in the weather, and the inducer itself moves hot exhaust that can carry moisture. Over the years many motors wear out at the bearings and start to drag, and steel parts around them rust. In the end the shaft stops turning.
A few signs often point to the inducer. The furnace starts its sequence and stops before the burners light, then tries again. You hear a hum from the furnace section with no fan noise behind it. Before it quits, an inducer can get louder over weeks, with a grinding or rattling sound, and the control board may blink a pressure switch code.
None of those signs proves the inducer has failed. A pressure switch, a blocked tube or the board can stop the sequence at the same point, which is why we test the draft and the switch before ordering a part.
The inducer runs only for heat. On a package unit that also cools, a seized inducer usually leaves the air conditioning working, and cooling problems are a separate story, covered on our central AC repair page.
What you can check and what to leave alone
Set the thermostat to heat, a few degrees above the room, check the filter and make sure the furnace breaker is on. If the furnace still won’t light, leave the service panels closed and call. Count the blink code if you can see the status light, and tell us what you hear.
If you smell gas, leave the home right away. Don’t flip switches, use a phone or light anything inside. Call SoCalGas at 1-800-427-2200 from a safe place outside, and book the repair only after the gas company has confirmed the home is safe. If your carbon monoxide alarm goes off, turn the heater off and call us. We measure the carbon monoxide, and if the heater is leaking, we shut it down and offer the repair or a replacement.
Our guide heater not working? what to check first goes through more checks symptom by symptom. Other heating jobs we’ve written up include a Goodman furnace in Burbank that couldn’t sense its flame, and on the cooling side, a Goodman package unit in Valley Village with a cracked drain pan. Gas wall heaters are their own kind of heater, like the ones in Los Feliz and Santa Monica.
Package unit and furnace repair in Sherman Oaks
We repair furnaces and package units in Sherman Oaks, in neighboring Studio City, Encino, Van Nuys and Valley Village, and across Los Angeles. The $85 service call covers the diagnosis and is credited toward the repair if you go ahead, and you get the price in writing before any work starts. We offer same-day visits when the schedule allows. Repairs carry a 30-day labor warranty and a 90-day warranty on parts we supply. CA BEAR registered (#A 50636). See furnace and heater repair and our HVAC services, or call (213) 205-2055 and tell us the brand on the unit’s label and what the furnace does when it tries to start.
FAQ
What does the draft inducer do on a gas furnace?
It creates the draft that carries exhaust out of the furnace. It's the first part to start on a call for heat, and the furnace won't light until a pressure switch confirms that draft.
What happens when the inducer motor seizes?
In general, the wheel can't spin, so there's no draft, the pressure switch doesn't close and the furnace doesn't light. You may hear the motor hum without turning, or the furnace may start its sequence and stop before ignition, and many control boards flash a pressure switch code. On the Goodman package unit in Sherman Oaks, the motor had seized from age.
Can you replace only the inducer motor?
On some models, yes, if the blower wheel can be taken off the old motor shaft. After years on a roof that wheel is often rusted on. On the Goodman unit in Sherman Oaks, the motor, the wheel and the housing are one part, so we replaced the whole assembly.
Does a package unit have the same inducer as an indoor furnace?
It does the same job. A gas/electric package unit puts a gas furnace and an air conditioner in one outdoor cabinet, and the furnace half starts with its inducer just like a furnace in an attic or a closet. The AC half doesn't use the inducer.
Have you repaired package units in Sherman Oaks?
Yes. In early November 2026, on an older Goodman package unit in Sherman Oaks, we replaced the draft inducer on the gas furnace side after its motor seized from age. We repair the heating and cooling sides of package units across Los Angeles. The $85 service call is credited toward the repair if you go ahead, and you get the price in writing after diagnosis. Call (213) 205-2055.
AC, heater or mini-split acting up? We cover LA and the Valley.
Call (213) 205-2055 or text a photo of the unit and its model sticker.