Quick facts

Service call $85 — credited toward the repair when you proceed
Warranty 30-day labor · 90 days on parts we supply
Credentials BEAR #A 50636 · EPA Section 608 Universal
Hours Mon–Fri 09:00–19:00
Sat–Sun 10:00–16:00

Igniters and flame sensing

A cold igniter or burners that light and go out: we check the part and whether the board is doing its job before replacing either.

Control boards

The board runs the whole startup sequence. We rule out the igniter, sensor, switches and wiring before we call a board bad.

Pressure switches and inducers

The board won't light the burners until the pressure switch proves the inducer is pulling draft. We test the switch, the tubing and the inducer.

Blower motors, including variable-speed

A variable-speed motor and its board can fail the same way. A tester runs the motor on its own, so we replace the part that failed.

Heat pumps and package units

Heat-pump heating and package units with a gas furnace inside, on the roof or on a pad.

Book online in Spanish

Online booking in both languages.

How a heating repair visit works

  1. Tell us what the furnace is doing

    Call or book online: no heat at all, burners that light and go out, a blower that runs cold, a blinking status light, or a wall heater pilot that won't stay lit. Count the blinks through the window in the furnace door if you can.

  2. Diagnosis on site

    The $85 service call covers the diagnosis. We follow the startup sequence step by step with a meter: thermostat call, inducer, pressure switch, igniter, flame sensing and blower.

  3. Written quote before the work

    You get a written flat-rate quote after diagnosis. If you go ahead, the $85 is credited toward the repair.

  4. Repair, then a full heat cycle

    After the repair we run the furnace through a complete heating cycle and watch every step come on in order.

  5. Warranty

    30 days on labor and 90 days on parts we supply. Parts you supply yourself carry no warranty from us.

What does furnace and heating repair cover?

Epic Star repairs home heating across Los Angeles: gas furnaces, gas wall heaters, heat pumps, and rooftop or ground package units with a gas furnace inside. We diagnose on site for an $85 service call, credited toward the repair when you proceed, then give you a written flat-rate quote. We repair igniters, flame sensing, pressure switches, gas valves, control boards and blower motors. If the heat goes out, call as early as you can: we offer same-day service when the schedule allows.

How does a gas furnace start, and where does it fail?

Once the thermostat calls for heat, the control board runs the furnace through a fixed order. It starts the inducer fan, which pulls air through the heat exchanger and out the vent, and waits for the pressure switch to confirm that draft. Then it powers the igniter until it glows, opens the gas valve, and watches the flame sensor for proof that the burners lit. Last, it starts the blower that pushes warm air through the house. A furnace that won’t heat has stopped at one of those steps, and the step tells us where to look.

Why won’t the igniter start?

In Porter Ranch, an attic furnace wasn’t starting its igniter, although the igniter itself was good. The board decides when the igniter gets power, so a good igniter that stays cold points back to the board. We replaced the control board and the furnace worked normally.

Old furnace control board held in a gloved hand in front of the open furnace, with the new board wired in behind it
A furnace control board replacement: the old board in hand, the new one wired in behind it.

Why do the burners light and then go out?

The flame sensor is a metal rod that sits in the flame. If the board doesn’t get proof of flame, it shuts the gas off within seconds and tries again, and after a few tries it can lock itself out. On a Goodman furnace in Burbank, the rod and its wiring checked out, so the fault was the board, and that’s what we replaced. A dirty rod can cause the same symptom, which is why we check the simple part first.

What does the pressure switch do?

The pressure switch proves that the inducer is pulling air through the furnace before the board lets it light. A switch that won’t close, a cracked or blocked tube, or a weak inducer stops the sequence there, and the status light may show a fault code. We test the switch and the inducer with a meter before replacing either. When the igniter glows and the burners still don’t light, we check whether the board is sending the gas valve its signal.

Furnace pressure switches held in a gloved hand in front of an open furnace, with a meter on the floor below
Pressure switches out of a furnace for testing.

What if the gas valve doesn’t open?

If the board is sending that signal, the gas supply to the furnace is on, and the burners still don’t light, the valve itself is next. We measure the signal right at the valve, so we know the board did its part before we condemn the valve. Then we replace the furnace gas valve and watch the burners light and stay lit through a full heat cycle.

Is it the blower motor or the control board?

A variable-speed blower motor takes its commands from the board, and a failure on either side can look the same. Several companies had looked at a Lennox furnace in Woodland Hills without pinning it down. We used a universal ECM tester, which runs the motor on its own, separate from the board. The motor was faulty and the board was fine, so we replaced only the motor. On these systems both parts are expensive, so testing before ordering matters.

Technician testing furnace wiring with a clamp meter
Testing furnace wiring with a clamp meter before any part is replaced.

What goes wrong when you first turn the heat on?

Check the filter before anything else: a clogged one can cause both cold air and short cycling.

Cold air from the vents

If the thermostat fan is set to On, the blower also runs between heat cycles and moves room-temperature air that feels cold on your hand. Auto fixes that. If the fan is on Auto and the air stays cold, the burners didn’t light or didn’t stay lit, and the steps above tell us where the sequence stopped. A clogged filter gives you cold air another way: the furnace overheats, the limit switch shuts off the burners, and the blower keeps running to cool the heat exchanger.

A burning smell

The first time the heat runs after months off, dust that settled on the burners and heat exchanger burns off, and you smell it at the vents. That’s normal, and it fades as the furnace runs. A smell that keeps coming back, or smells like hot plastic or wiring, is a reason to turn the furnace off at its switch and call, since a blower motor or a wire can be overheating. A rotten-egg smell is gas. Leave the house and call the gas company from outside.

Turning on and off (short cycling)

A clogged filter starves the furnace of air. The heat exchanger runs hot, the limit switch shuts off the burners, the furnace cools and starts again, and the loop repeats. A limit switch that has gone weak trips the same way with a clean filter. If the burners light and go out within seconds, over and over, the furnace isn’t proving its flame, which points to the sensor rod, its wiring or the board. We check the filter, test the limit switch and watch the flame signal before replacing a part.

Gas wall heater repair

We repair gas wall heaters, including the Williams, Empire and Cozy wall furnaces that heat many older Los Angeles apartments and houses in place of a central furnace.

A wall heater with a standing pilot keeps a small flame burning that lights the main burner when the thermostat calls for heat. The pilot heats a thermocouple or a thermopile, which makes a small voltage that holds the gas valve open. So when the pilot won’t light, or goes out as soon as you let go of the knob, we check the pilot assembly, the thermocouple or thermopile, and the gas valve. If the pilot stays lit and the burner doesn’t come on, the wall thermostat and its wiring join the list. A burner that shuts off after a few minutes of running can point to a limit switch.

We test those parts before we replace anything, gas valve included, then run the heater through a full heat cycle. To book, call (213) 205-2055 or book online, and tell us the brand on the label and what the pilot is doing. The $85 service call covers the diagnosis and is credited toward the repair when you proceed.

Two recent wall heater jobs: In Los Feliz, a wall heater whose flame barely burned and wouldn’t adjust got a new gas valve, and a new thermocouple in the same visit, because the old one turned out rusty all over and badly burnt. In Santa Monica, a wall heater with the pilot out and nothing lighting needed a new thermopile, and it works now.

When to stop using a wall heater

A wall heater sends its exhaust outside through a vent. If that vent is blocked or has come apart, exhaust carrying carbon monoxide can stay in the home, so don’t run a heater with a damaged vent, and keep a working carbon monoxide alarm. If the alarm goes off, turn the heater off and call us. We measure the carbon monoxide, and if the heater is leaking, we shut it down and offer the repair or a replacement.

If the pilot has simply gone out, the lighting instructions are on a label on the heater; if it won’t light or won’t stay lit after that, stop and call. If you smell gas, leave the home right away. Don’t flip switches, use a phone or light anything inside. Call SoCalGas at 1-800-427-2200 from a safe place outside, whether the smell is faint or strong, and book the repair only after the gas company has confirmed the home is safe.

Do you repair heat pumps and package units?

Yes. A heat pump heats with the same refrigerant circuit that cools, run in reverse. When it blows cold in heat mode, we check the outdoor unit first: a capacitor, a contactor, a fan motor or a leak, the same parts we cover on our central AC repair page. A heat pump in heat mode also pauses now and then to melt frost off its outdoor coil, and the outdoor unit may steam while it does. That defrost is normal, and our mini-split repair page explains how to tell it from a fault.

Many rooftop and ground package units carry a gas furnace in the same cabinet as the air conditioner, so the heating side has the same igniter, sensor, switches, board and blower as an indoor furnace. On a pharmacy’s rooftop gas pack in Encino, the unit flashed a limit-switch fault although every switch tested good; the control board had cracked solder joints, and we reflowed them on the roof. Rooftop units at businesses are covered on our commercial AC and HVAC repair page. On a Goodman package unit in Sherman Oaks, the draft inducer motor had seized from age, and we replaced the whole inducer assembly, since on that unit the motor, wheel and housing are one part.

Rooftop package unit with its blower assembly pulled out and the old blower motor on the roof beside it
Package-unit heating and blower service on a roof: the blower assembly out and the old motor beside it.

What can I check before I call?

Check that the thermostat is set to heat and above room temperature, that the filter isn’t clogged, and that the furnace’s power switch is on. Count the blinks of the status light through the small window in the door; that code tells us where the sequence stopped. Don’t open the burner compartment or touch the igniter. If you smell gas, leave the house and call the gas company from outside.

For a symptom-by-symptom checklist (no heat, cold air, burners that light and go out, a smell on the first start, gas wall heater pilots, heat pumps), see heater not working? what to check first.

How much does furnace repair cost in Los Angeles?

Ranges come from repairs we completed in Los Angeles, rounded, and include parts, labor and the $85 service call. Your exact price is quoted in writing after diagnosis, before any work starts.

Repair categoryTypical costOur LA jobs
Furnace control board$430–$6302 jobs
Variable-speed (ECM) blower motor$1,450–$2,0001 job
Rooftop gas pack: control board repaired at board level$220–$3101 job

The service call is $85, and it’s credited toward the repair when you proceed. After diagnosis you get a written flat-rate quote, before we start. Gas wall heaters and furnace gas valves are quoted the same way. Repairs carry a 30-day labor warranty and 90 days on parts we supply; parts you supply yourself carry no warranty from us. We repair the furnace and its controls; we don’t do gas piping. For thermostat swaps, see thermostat installation. AC, mini-split, commercial and appliance repairs are in our Los Angeles repair cost guide.

Credentials

California BEAR registered (#A 50636), EPA Section 608 Universal certified, $1,000,000 general liability insurance. Online booking in English and Spanish.

Service area

We serve all of Los Angeles: the San Fernando Valley, Hollywood and Mid-City, the Westside, and the beach cities and South Bay.

Call (213) 205-2055

Tell us what the furnace is doing and what the status light shows.

Recent heating repairs we've documented

  • Porter Ranch

    A good igniter that never got power

    What the customer saw
    An attic furnace in Porter Ranch wasn't starting its igniter.
    What we found
    The igniter itself was good. On this furnace the control board decides when the igniter gets power, so a good igniter that stays cold pointed back to the board.
    What we did
    We replaced the control board, and after that the system worked normally.
  • Burbank

    Goodman furnace that couldn't sense its flame

    What the customer saw
    A Goodman furnace in Burbank wasn't sensing its flame: the burners lit, but the board never got proof that they had.
    What we found
    The flame sensor is just a metal rod in the flame. With the rod and its wiring ruled out, the fault was the control board.
    What we did
    We replaced the control board on this furnace.
  • Woodland Hills

    Lennox furnace: control board or variable-speed blower motor?

    What the customer saw
    Several companies had already looked at this Lennox furnace in Woodland Hills without pinning down the problem.
    What we found
    With a variable-speed blower, a failing board and a failing motor can look the same. A universal ECM tester ran the motor on its own, apart from the board, and showed the motor was faulty and the board fine.
    What we did
    We replaced the blower motor, and the system worked normally after that.
  • Encino

    Pharmacy gas pack with no heat

    What the customer saw
    A pharmacy in Encino lost its heat. The packaged unit on the roof had shut its burners down and was flashing "high limit switch open."
    What we found
    All three limit switches tested closed and the wiring had continuity. On the back of the control board, the solder joints at the safety-circuit connector had ring cracks.
    What we did
    We reflowed the cracked joints right on the roof instead of replacing the board. The board read the switches correctly, the burners lit and the pharmacy had heat again.

    Watch: a real job in Encino

    Pharmacy gas pack with no heat
  • Los Feliz

    Gas wall heater with a weak flame that wouldn't adjust

    What the customer saw
    A gas wall heater in Los Feliz was barely burning, and its flame couldn't be adjusted.
    What we found
    The gas valve controls the gas to the pilot and the burner, and it was the part we replaced. While we were replacing it, the thermocouple turned out to be rusty all over and badly burnt.
    What we did
    We replaced the gas valve with a Robertshaw part and replaced the thermocouple in the same visit.
  • Santa Monica

    Gas wall heater with the pilot out and nothing lighting

    What the customer saw
    A gas wall heater in Santa Monica wasn't working at all: the pilot wasn't burning and nothing would ignite.
    What we found
    On many millivolt wall heaters, the thermopile in the pilot flame makes the voltage that runs the gas valve. On this heater, the thermopile was the part to replace.
    What we did
    We replaced the thermopile, and the heater works now.
  • Sherman Oaks

    Goodman package unit with a seized inducer motor

    What the customer saw
    On the gas furnace side of a rooftop Goodman package unit in Sherman Oaks, the draft inducer motor had seized from age.
    What we found
    The furnace can't light until the pressure switch proves the inducer's draft. On this unit, the motor, the blower wheel and the metal housing are one part.
    What we did
    We replaced the whole inducer assembly.

Photos from our heating jobs

A furnace control board held in a gloved hand in front of an open furnace, with a replacement control board's box on the floor
Attic furnace whose igniter wouldn't start, although the igniter itself was good: the control board was replaced.📍 Porter RanchRead the full case
Old furnace control board held in a gloved hand in front of an open Goodman furnace, with the new board wired in behind it
Goodman furnace that wasn't sensing flame: the sensor and its wiring checked out, so the control board was replaced.📍 BurbankRead the full case
An orange universal ECM tester in a gloved hand, clipped to the terminal strip of the control board inside a Lennox furnace, with both indicator lights on
Lennox furnace: a tester ran the variable-speed blower motor apart from the control board. The motor was bad and the board was fine, so the motor was replaced.📍 Woodland HillsRead the full case
Commercial packaged HVAC unit on a pharmacy roof with its service panels open, meters and a tool bag set on top
Pharmacy gas pack with no heat and a "high limit switch open" fault: the limit switches tested good, so the fault was traced to the control board.📍 EncinoRead the full case
Old gas furnace replaced with a new one by Epic Star in Studio City, CA
Gas furnace replaced, heat restored for a Studio City homeowner📍 Studio City
Tall cream-colored gas wall heater in a hallway, with a long front grille, a smaller grille at the bottom and a light switch on the wall beside it
Gas wall heater in Los Feliz whose flame barely burned and couldn't be adjusted; we replaced the gas valve, and the thermocouple too, which was rusty and badly burnt.📍 Los FelizRead the full case
Tall white gas wall heater in the corner of a room, with a long front grille and a smaller grille at the bottom
Gas wall heater in Santa Monica that wasn't working at all, with the pilot out and nothing lighting; we replaced the thermopile, and the heater works now.📍 Santa MonicaRead the full case
Gray Goodman package unit on a flat white roof, with the condenser fan grille on top, louvered panels on one side and two sheet-metal hoods on the service side
Goodman package unit in Sherman Oaks: the draft inducer motor on its gas furnace side had seized from age, and we replaced the whole inducer assembly.📍 Sherman OaksRead the full case

Issues we fix

  • Furnace makes its startup sounds but the burners never light

    Possible causes:

    • Control board not sending power to the igniter
    • Failed igniter
    • Pressure switch not proving draft
  • Burners light, then shut off within seconds

    Possible causes:

    • Flame not being sensed: dirty sensor rod, wiring or the control board
  • Furnace runs but the blower doesn't move air

    Possible causes:

    • Failed blower motor, including variable-speed ECM motors
    • Control board not commanding the motor
  • Status light blinking a fault code

    Possible causes:

    • Pressure switch or inducer fault
    • Flame-sensing fault
    • Limit switch open
  • Heater blowing cold air

    Possible causes:

    • Thermostat fan set to On instead of Auto, so the blower runs between heat cycles
    • Burners not lighting or not staying lit: igniter, flame sensing or pressure switch
    • Clogged filter tripping the limit switch, which shuts off the burners while the blower keeps running
  • Burning or dusty smell when the heat first comes on

    Possible causes:

    • Dust burning off the burners and heat exchanger on the first runs of the season; it fades on its own
    • A smell that stays, or smells like hot plastic or wiring: an overheating blower motor or wire
    • A rotten-egg smell is gas: leave the house and call the gas company from outside
  • Furnace keeps turning on and off (short cycling)

    Possible causes:

    • Clogged filter tripping the limit switch
    • Weak limit switch tripping early
    • Flame-sensing fault: burners light, shut off within seconds and try again
  • Heat pump blowing cold in heat mode

    Possible causes:

    • Outdoor unit not running: capacitor, contactor or fan motor
    • Low refrigerant from a leak
  • Package unit on the roof won't heat

    Possible causes:

    • Safety switch or control board fault
    • Blower motor failure
  • Gas wall heater pilot won't light or won't stay lit

    Possible causes:

    • Dirty or clogged pilot assembly giving a weak flame
    • Thermocouple or thermopile no longer making enough voltage to hold the gas valve open
    • Failed gas valve
  • Wall heater pilot is lit but the burner doesn't come on

    Possible causes:

    • Wall thermostat or its wiring
    • Weak thermopile output
    • Failed gas valve

Frequently asked questions

Why won't my furnace turn on?

Check the thermostat, the filter and the furnace's power switch first. If the furnace makes its startup sounds but the burners never light, possible causes are a control board that doesn't power the igniter, a failed igniter, or a pressure switch that never proves draft. Count the status-light blinks through the window in the door and call. Don't open the burner compartment yourself.

Why does my furnace light and then shut off?

It may not be able to prove its flame. A flame sensor is a metal rod that sits in the flame and tells the control board the burners have lit. If the board doesn't get that signal, it shuts the gas off within seconds, tries again and can lock itself out. On a Goodman furnace in Burbank, the rod and its wiring checked out and the control board was the fault.

Why is my heater blowing cold air?

Check the thermostat first. With the fan set to On, the blower keeps running between heat cycles, and that air feels cold; set it to Auto. If it's on Auto and the air doesn't warm up, the burners didn't light or didn't stay lit, so the startup sequence stopped at the igniter, the flame sensor or the pressure switch. A clogged filter can cause it too: the furnace overheats, the limit switch shuts off the burners, and the blower keeps running. Replace a dirty filter, and call if the air still comes out cold.

Is a burning smell normal when I first turn on the heat?

On the first runs of the season, a dusty, burning smell is usually dust burning off the burners and the heat exchanger, and it fades as the furnace runs. If it doesn't fade, or it smells like hot plastic or wiring, turn the furnace off at its switch and call, because a blower motor or a wire may be overheating. A rotten-egg smell is gas: leave the house and call the gas company from outside.

Why does my furnace keep turning on and off?

That's called short cycling. Check the filter first. A clogged filter starves the furnace of air, the heat exchanger runs hot, and the limit switch shuts off the burners until it cools, then the furnace starts again. A weak limit switch can trip the same way with a clean filter. If the burners light and go out within seconds, over and over, look at flame sensing instead: a dirty sensor rod, its wiring or the control board.

Do you replace furnace gas valves?

Yes. If the igniter glows and the control board sends the gas valve its signal, but the burners still don't light, the valve is the next suspect. We check that signal at the valve with a meter, so we know the board did its part, and replace the valve if it has failed. We replace gas valves on wall heaters too.

How much does furnace repair cost in Los Angeles?

On heating repairs we completed in Los Angeles, a furnace control board typically runs $430–$630, a board-level repair on a rooftop gas pack $220–$310, and a variable-speed (ECM) blower motor $1,450–$2,000. Those ranges include parts, labor and the $85 service call, which is credited toward the repair when you proceed. Your exact price comes as a written flat-rate quote after diagnosis, before any work starts, and completed repairs carry a 30-day labor warranty and 90 days on parts we supply.

Is it the control board or the blower motor?

On a furnace with a variable-speed blower, a failure on either side can look the same, because the board commands the motor. We use a universal ECM tester that runs the motor on its own. On a Lennox furnace in Woodland Hills, the tester showed the motor was bad and the board was fine, so only the motor was replaced.

Do you repair heat pumps and package units for heating?

Yes. A heat pump heats with the same refrigerant circuit that cools, run in reverse, so its heating problems can start at the outdoor unit. Many rooftop and ground package units have a gas furnace in the same cabinet as the AC, and we repair their heating side too: blowers, safety switches and control boards.

Why won't my wall heater pilot stay lit?

If the pilot goes out as soon as you let go of the knob, the thermocouple or thermopile may not be making enough voltage to hold the gas valve open, the pilot assembly may be dirty and its flame too weak to heat it, or the gas valve has failed. Relight it once using the instructions on the heater's label. If it still won't stay lit, stop and call us. If you smell gas, leave and call SoCalGas from outside.

Do you repair wall heaters in apartments?

Yes. Many older LA apartments heat with a gas wall heater instead of a central furnace, often a Williams, Empire or Cozy unit, and we repair them. If the pilot won't light or won't stay lit, we check the pilot assembly, the thermocouple or thermopile and the gas valve; if the pilot is lit and the burner doesn't come on, we also check the wall thermostat and its wiring. The $85 service call is credited toward the repair when you proceed, and you get a written flat-rate quote after diagnosis.

Do you replace furnace inducer motors?

Yes. The inducer is the small blower that starts first and creates the draft the pressure switch has to prove, so a seized inducer motor leaves the furnace unable to light. On some models only the motor can be replaced, if the blower wheel comes off the old shaft; on others the motor, wheel and housing are one assembly. On a Goodman package unit in Sherman Oaks, the inducer motor had seized from age, and we replaced the whole assembly.

Do you work on gas piping?

No. We repair the furnace itself and its controls; we don't run or repair gas piping. If you smell gas, leave the house and call the gas company from outside.

What credentials and insurance do you carry?

Epic Star Inc is California BEAR registered (#A 50636) and carries $1,000,000 in general liability insurance. Our technician is EPA Section 608 Universal certified for refrigerant work on heat pumps and AC systems.

Verified source

Google reviews

Selected Google reviewsView at source

★★★★★

Eric had a great and warmness about himself, efficient and knowledgeable awareness of the issues. Had accessed and completed the task in a minimal amount of time (12 minutes)
Delma Braddy12 hours ago

★★★★★

Refrigerator was checked thoroughly and repair ok ok
Clara Cruz6 days ago

★★★★★

I’m very glad I had Ivan come to clean the extremely dirty hood over my stove. He came the same afternoon and did a very thorough job. After seeing how much work it was, I was very pleased with the price he charged me. I would definitely recommend this company.
Claire Hartunian2 weeks ago
Same-day service

Book a diagnostic/repair visit

Please enter your name.
Enter a valid 10-digit US phone number
Please enter a valid email.
Please enter your city or ZIP.
Use JPG, PNG, or WebP — max 3 × 5MB.
No spam, ever Background-checked techs

No heat? Book a furnace diagnosis.

Or text a photo of the furnace's rating plate and tell us what the status light is doing.