A gas wall heater in Santa Monica with the pilot out and nothing lighting: a new thermopile
Nothing on this wall heater worked. The pilot wasn't burning and nothing would ignite. We replaced the thermopile, and the heater works now.
In this guide
The pilot on this gas wall heater in Santa Monica was out. We replaced the thermopile, and the heater works now.
What the customer saw
The heater in the photo at the top is a tall white wall unit in the corner of a room, with a long grille across the front and a smaller grille at the bottom. Nothing on it worked. There was no pilot flame, and nothing would light.
What a thermopile does
Many gas wall heaters have a standing pilot, a small flame that burns all the time and lights the main burner when the wall thermostat calls for heat. On a millivolt heater, a thermopile sits in that pilot flame. It’s a bundle of small thermocouples joined together, and heat from the pilot makes it produce a few hundred millivolts. That’s what powers the gas valve. The heater doesn’t need house electricity to run.
On many millivolt wall heaters, the voltage does two jobs. It holds the valve’s pilot safety open, so the pilot gas stays on after you let go of the knob. And when the thermostat closes, the same voltage opens the valve to the main burner. When the thermopile fails on such a heater, neither the pilot nor the burner stays lit, and from the outside the heater looks dead.
Other heaters use a separate thermocouple for the pilot. On a wall heater in Los Feliz, we replaced a rusty, badly burnt thermocouple along with the gas valve.
The fix: a new thermopile
On this Santa Monica heater, we replaced the thermopile. The heater works now.

This photo looks into the heater from the front. The burner is lit, with flame along its tube. The pilot assembly sits in front of the burner, and its tube and thin leads run down toward the bottom of the photo.
When a wall heater pilot won’t light
This section is general. It isn’t a report of what we found in Santa Monica.
When nothing lights on a wall heater, the cause can be the gas being off at the heater’s valve or at the supply, a clogged pilot opening, a dead spark igniter, the thermopile or thermocouple, or the gas valve itself. If the pilot lights while you hold the knob but goes out when you let go, that points to the part in the pilot flame or to the valve. If the pilot stays lit and the burner doesn’t come on, the wall thermostat and its wiring join the list.
What you can do yourself is follow the lighting instructions on the heater’s label, step by step, including the wait after you turn it off. If the pilot won’t light or won’t stay lit after that, stop and call. Don’t take the burner cover off, and don’t reach into the burner with a lighter.
If you smell gas, leave the home right away. Don’t flip switches, use a phone or light anything inside. Call SoCalGas at 1-800-427-2200 from a safe place outside, and book the repair only after the gas company has confirmed the home is safe. If your carbon monoxide alarm goes off, turn the heater off and call us. We measure the carbon monoxide, and if the heater is leaking, we shut it down and offer the repair or a replacement.
For more safe checks, see heater not working? what to check first.
Wall heater repair in Santa Monica
Need a wall heater looked at in Santa Monica or elsewhere in Los Angeles? Call (213) 205-2055 or book online, and tell us what the pilot is doing and, if you can see it, the brand on the label. The visit is an $85 service call, and that $85 is credited to the repair if you go ahead with it. You get the price in writing first, and we can often come the same day when the schedule allows. Our work carries a 30-day labor warranty, and parts we supply carry 90 days. CA BEAR registered (#A 50636). More on heating: furnace and heater repair.
FAQ
What does a thermopile do in a gas wall heater?
On many millivolt wall heaters, the thermopile sits in the pilot flame and turns that heat into a small voltage, a few hundred millivolts. That voltage holds the pilot valve open and powers the main gas valve, so the heater doesn't need house power, and when the thermopile fails neither the pilot nor the burner stays lit. Other heaters use a separate thermocouple for the pilot.
Why won't my wall heater pilot light or stay lit?
In general, the gas may be off at the heater's valve or the supply, the pilot opening may be clogged, the spark igniter may be dead, or the part in the pilot flame that holds the valve open (a thermopile or a thermocouple) may have failed. On a gas wall heater in Santa Monica where the pilot wasn't burning and nothing would ignite, we replaced the thermopile.
Is a thermopile the same as a thermocouple?
No, although both sit in the pilot flame. A thermocouple makes a very small voltage that only holds the valve's pilot safety open. A thermopile makes more, enough to run a millivolt gas valve and its wall thermostat. On a wall heater in Los Feliz we replaced a rusty, badly burnt thermocouple together with the gas valve; on this Santa Monica heater it was the thermopile.
Do you repair gas wall heaters in Santa Monica?
Yes, in Santa Monica and across Los Angeles, including the pilot, the thermopile or thermocouple and the gas valve. The $85 service call is credited toward the repair if you go ahead, and you get the price in writing after diagnosis. Call (213) 205-2055 and tell us what the pilot is doing.
AC, heater or mini-split acting up? We cover LA and the Valley.
Call (213) 205-2055 or text a photo of the unit and its model sticker.